| This line of DIFFERENTIAL CALIBRATION SUBSTRATES allows the user to calibrate any microwave probehead at the probe tip. The underlying principal of the calibration of a measurement system is to provide accurate known standards to which the measurement system can be connected. Each calibration substrate contains highly precise elements for calibrating out the unavoidable errors and losses in a microwave network analyzer, its associated cabling, and the microwave probe to ensure accurate on-wafer testing. | - Supports Precise SOLT, LRL and LRM calibrations
- Includes CalKit software for easy loading to Network Analyzer
- Pitch range from 100 to 1250 microns
- Suitable for all probes® from DC to 110 GHz
- Available for GSGSG and GSSG Footprints
- Load standards individually trimmed to 0.25% accuracy
- 25 mil (635 micron) thick alumina substrate
| 
| Accurate, easy to use calibration substrates, calibration coefficients, and detailed instructions allow you to precisely calibrate the measurement system to the probe tips. The typical elements for calibrating a microwave measurement system consists of opens, shorts, 50 ohm loads, and throughs. Precision crafted calibration substrates, when properly used, assure you of accurate on-wafer test results. All load standards are individually inspected and trimmed to within 0.25% accuracy using NIST traceable equipment. Easy to use step by step instructions are provided for use with Agilent ENA four port network analyzers and Agilent PNA network analyzers with PLTS software. | Differential Calibration Substrate Selection Guide | Calibration Substrate | Pad Size (microns) | Calibration Types Supported | Footprint | Pitch | PSGCS2100 | 50 x 50 | SOLT, LRL, LRM | GSGSG | 100 | PSGCS2125 | 50 x 50 | SOLT, LRL, LRM | GSGSG | 125 | PSGCS2150 | 50 x 50 | SOLT, LRL, LRM | GSGSG | 150 | PSGCS2200 | 50 x 50 | SOLT, LRL, LRM | | GSGSG | 200 | PSGCS2250 | 50 x 50 | SOLT, LRL, LRM | | GSGSG | 250 | PSGCS2500 | 100 x 100 | SOLT, LRL, LRM | | GSGSG | 500 | Table 2 | PSGCS3100 | 50 x 50 | SOLT, LRM | | GSSG | 100 | PSGCS3125 | 50 x 50 | SOLT, LRM | | GSSG | 125 | PSGCS3150 | 50 x 50 | SOLT, LRM | | GSSG | 150 | PSGCS3200 | 50 x 50 | SOLT, LRM | | GSSG | 200 | PSGCS3250 | 50 x 50 | SOLT, LRM | | GSSG | 250 | PSGCS3450 | 100 x 100 | SOLT, LRM | | GSSG | 450 | PSGCS3500 | 150 x 150 | SOLT, LRM | | GSSG | 500 | PSGCS3600 | 100 x 100 | SOLT, LRM | | GSSG | 600 | PSGCS3800 | 300 x 300 | SOLT, LRM | | GSSG | 800 | PSGCS31000 | 300 x 300 | SOLT, LRM | | GSSG | 1000 | PSGCS31250 | 300 x 300 | SOLT, LRM | | GSSG | 1250 | Table 3 | SOLT = Short-Open-Load-Through LRL = Line-Reflect-Line LRM = Line-Reflect-Match |
|